Hantek HSA2016 Series Spectrum Analyzer can be used in laboratory, more suitable for field mobile use.
Features:
- Frequency range :9KHz~1.6GHz;
- Optimal sensitivity: -161dBm;
- RBW:10Hz to 1MHz.
- High protection portable design, sturdy and durable
- can be used in laboratory, more suitable for field mobile use
- built-in large capacity lithium battery, can work for more than 4 hours. 18650 rechargeable battery.
- USB/LAN communication, easy for long-range control.
- 5.6 inch highlight color display, 640*480 resolution, waveform display clearly.
Specifications:
| Model | HSA2016A | HSA2016B | |
| Frequency Range | 9KHz~1.6GHz AC Coupled | 9KHz~1.6GHz AC Coupled 5M~1.6GHz TG | |
| Frequency Resolution | 1Hz | ||
| Reference Frequency | 10MHz | ||
| Frequency Readout Accuracy | ±(frequency indication*frequency reference uncertainty+1%*span+20%RBW+marker resolution+1Hz) | ||
| Internal 10MHz Reference Accuracy | Aging rate | ±1ppm/year(0℃~50℃,Reference is 25℃) | |
| Temperature stability | ±1ppm/year | ||
| Marker Resolution | (Frequency span)/(number of sweep points-1) | ||
| -3dB Bandwidth |
10Hz to 1MHz,1-3-10 sequence
|
||
| Accuracy | ±5% RBW=10Hz~1MHz nominal | ||
| Resolution Filter Shape Factor | <5:1 nominal | ||
| Video Bandwidth (VBW) | -3dB bandwidth | 1Hz to 1MHz,1-3-10 sequence | |
| Accuracy | ±10% VBM=1Hz~1MHz nominal | ||
| Displayed Average Noise Level (normalized to1Hz) | |||
| 9K~1MHz | Preamp off | -108dBm,typical -127dBm | |
| 1MHz ~10MHz | -128dBm,typical -146dBm | ||
| 10MHz ~500MHz | -142dBm,typical -146dBm | ||
| 500MHz ~2.5GHz | -141dBm,typical -145dBm | ||
| 2.5GHz ~3GHz | -140dBm,typical -144dBm | ||
| 9K~1MHz | Preamp on | -131dBm,typical -150dBm | |
| 1MHz ~10MHz | -148dBm,typical -163dBm | ||
| 10MHz ~500MHz | -161dBm,typical -164dBm | ||
| 500MHz ~2.5GHz | -159dBm,typical -162dBm | ||
| 2.5GHz ~3GHz | -158dBm,typical -161dBm | ||
| SSB Phase Noise | Carrier Offset(20℃~30℃,500MHz Central Frequency) | 10K | < -92 dBc/Hz, typical -95 dBc/Hz |
| 30K | < -93 dBc/Hz, typical -96 dBc/Hz | ||
| 100K | < -95 dBc/Hz, typical -97 dBc/Hz | ||
| 1MHz | < -117 dBc/Hz, typical -119 dBc/Hz | ||
| Range | Span >100Hz | 2ms to 1000s | |
| Span=0Hz | 600ns to 200s | ||
| Sweep Mode | Continuous, single | ||
| Trigger Source | Free run; video; external | ||
| Trigger slope | Selectable positive or negative edge | ||
| Trigger delay | Span =0Hz | ±12ms to ±12s nominal | |
| Frequency Counter | Counter Resolution | 1Hz | |
| Accuracy | ± (marker frequency × frequency reference uncertainty + counter resolution) | ||
| Log Scale and Units | 1 to 10 dB/divisions in 1, 2, 5, 10 dB steps, 10 divisions displayed | ||
| Linear Scale and Units | 0 to 100%,10 divisions displayed | ||
| Scale Unit | dBm,dBmV,dBuV,Watts,Volts | ||
| Sweep (Trace) Points | 461 | ||
| Number of Markers | 4 | ||
| Detectors | Normal, positive peak, dample, negative peak, RMS | ||
| Number of Traces | 4 | ||
| Trace Functions | Clear/write, maximum hold, minimum hold, average, check,close | ||
| Level Measurement Error |
±1.5dB(excluding input VSWR mismatch)
20~30℃,peak detector, preamplifier off, input signal -50dBm to 0dBm
|
||
| Setting Range | -100dBm to +30dBm, steps of 1dB | ||
| Setting Resolution | Log scale: 0.01dB | Linear scale: Almost log(2.236μV to 7.07V) | |
| Maximum Safety Input Level | Average continuous power: +33dBm | DC input voltage: 50Vdc | |
| Measurement Range | 9KHz~2MHz | Displayed average noise level (DANL) to +10dB | |
| 2MHz~3GHz | Displayed average noise level (DANL) to +20dB | ||
| Input attenuator range | 0 to 51dB,1dB steps | ||
| Second Harmonic Distortion(SHI) | <65dBc,50MHz to 3GHz(Mixer level -30dBm,attenuator =0dB,preamp off,20℃~30℃) | ||
| Second Harmonic Distortion(SHI) | <65dBc,50MHz to 3GHz(Mixer level -30dBm,attenuator =0dB,preamp off,20℃~30℃) | |
| Third-OrderIntermodulation(TOI) | 50~300MHz | +8dBm,Third-order intermodulation products:2 x -20dBm; frequency separation 100KHz:attenuation = 0dB; preamp off,20℃~30℃ |
| 300MHz~1.6GHz | +10dBm | |
| Input Related Spurious | <-75dBc,(input mixer = -30dBm) | |
| Inherent Residual Response | <-90dBm,typical -98dBm (Input terminated and 0 dB RF attenuation, preamplifier off) | |
| RF Input VSWR (at Tuned Frequency) | 10MHz to 1.6GHz | <1.5:1, nominal Attenuator setting 10~20dB |
| Reference Iinput Frequency | 10MHz | |
| Reference Input Amplitude | 0~10dBm | |
| Trigger Voltage | 5V TTL level | |
| Connector and Output Impendence | N female;(50Ω) | |
Documents:
Package Includes:
- 1 x Hantek HSA2016 Series HSA2016A / HSA2016B Spectrum Analyzer
Related Products
Hantek DSO8000E Series DSO8072E / DSO8102E / DSO8152E / DSO8202E Handheld Oscilloscope
Six in one: Oscilloscope/Recorder/DMM/ Spectrum Analyzer/Frequency Counter/Arbitrary Waveform genera..
रo 84,756.85
Hantek HSA2030 Series HSA2030A / HSA2030B Spectrum Analyzer
Hantek HSA2030 Series Spectrum Analyzer can be used in laboratory, more suitable for field mobile us..
रo 493,970.53
Metravi AT-5010 Spectrum Analyzer
1050MHz Spectrum Analyzer.Specifications:Frequency range : 0.15— 1050 MHzCenter frequency display ac..