Fluke 17B MAX Inherits and continues the classic design of 17B+, with further improved functions: Input Alert Alarm, Simple interface to wake meter from sleep mode by activating any buttons, test leads with fine probes to help electricians and electronic R&D personnel make accurate measurements.

Key features:

  • Audible and visual alarm for incorrect connections
  • Test leads with fines tips for circuit board testing
  • Simple interface to wake meter from sleep mode by activating any buttons
  • Voltage: 6000-count reading
  • Capacitance range: 2000uF
  • Safety rating: CATIII 600V
  • Frequency and temperature measurement

Specifications:

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 % Accuracy specifications take the form of: ± ([% of Reading] + [Number of Least Significant Digits]).

FunctionRangeResolutionAccuracy
15B MAX17B MAX
AC Volts (40 Hz to 500 Hz)16.000 V
60.00 V
600.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
1.0 % + 31.0 % + 3
AC Millivolts600.0 mV0.1 mV3.0 % + 33.0 % + 3
DC Volts6.000 V
60.00 V
600.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.5 % + 30.5 % + 3
DC Millivolts600.0 mV0.1 mV1.0 % + 101.0 % + 10
AC Current μA (40 Hz to 400 Hz)2400.0 μA
4000 μA
0.1 μA
1 μA
1.5 % + 31.5 % + 3
AC Current mA (40 Hz to 400 Hz)240.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5 % + 31.5 % + 3
AC Current A (40 Hz to 400 Hz)24.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 31.5 % + 3
DC Current μA2400.0 μA
4000 μA
0.1 μA
1 μA
1.5 % + 31.5 % + 3
DC Current mA240.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5 % + 31.5 % + 3
DC Current A24.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 31.5 % + 3
Diode Test32.000 V0.001 V10%10%
Temperature 450.0 °C to 400.0 °C
0 °C to 50.0 °C
-55.0 °C to 0 °C
0.1 °CNA2 %+1 °C
2 °C
9 %+2 °C
Resistance (Ohms)5400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5 % + 3
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5 % + 3
Capacitance640.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
2000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
Frequency1 (10 Hz to 100 kHz)50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
NA0.1 % + 3
Duty Cycle11% to 99%0.10%NA1 % typical7
Continuity Threshold70Ω70Ω
BacklightYesYes
  • All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
  • Typical burden voltage: DC/AC Current µA: 100 µV / µA; DC/AC Current mA: 2 mV/mA; DC/AC Current A: 0.03 V/A
  • Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA
  • Use Type K thermocouple
  • Typical open circuit test voltage is 0.54 V, maximum short circuit current is 1.8 mA
  • Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
  • Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 %.
Input Characteristics
FunctionOverload ProtectionInput Impedance (Nominal)Common Mode Rejection RatioNormal Mode Rejection Ratio
AC Volts1000 V 1>10 MΩ, <100 pF>60 dB at 50 Hz or 60 Hz
AC Millivolts1000 V 1>1 MΩ, <100 pF>80 dB at 50 Hz or 60 Hz
DC Volts1000 V 1>10 MΩ, <100 pF>100 dB at 50 Hz or 60 Hz>60 dB at 50 Hz or 60 Hz
DC Millivolts1000 V 1>1 MΩ, <100 pF>80 dB at 50 Hz or 60 Hz

1106 V Hz max

General Specifications

  • Maximum voltage between any Terminal and Earth Ground 600 V
  • Maximum differential voltage between V and COM terminals 1000V
  • Display (LCD) 6000 counts, updates 3/sec
  • Battery Type 2 AA, IEC LR6
  • Battery life 500 hours minimum
  • Temperature Operating 0 °C to 40 °C;

                                    Storage -30 °C to 60 °C

  • Relative Humidity Operating Humidity Non-condensing

                                            (<10 °C); ≤90 % RH at 10 °C to 30 °C;

                                            ≤75 % RH at 30 °C to 40 °C

  • Operating Humidity, 40 MΩ range ≤80 % RH at 10 °C to 30 °C; ≤70 % RH at 30 °C to 40 °C
  • Altitude Operating 2000 m; Storage 12000 m
  • Temperature Coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
  • Fuse protection for current inputs 440 mA, 1000 V, fast-blow, use only Fluke

                                                                   specified parts. 11 A, 1000 V, fast-blow,

                                                                    use only Fluke specified parts

  • Size (HxWxL) 183 mm x 91 mm x 49.5 mm
  • Ingress Protection IP40
  • Safety IEC 61010-1, IEC61010-2-030: CAT III

                              600 V, Pollution Degree 2

  • Electromagnetic Environment IEC 61326-1: Portable
  • Electromagnetic Compatibility (EMC) Only applicable in Korea

Documentations:

Package Includes:

  • 1 x TL75 Test Leads with 2 Protective Caps
  • 1 x Type K Thermocouple
  • 1 x 2 AA Batteries
  • 1 x Safety information

Write a review

Please login or register to review

Fluke 17B MAX Digital Multimeter

  • Brand: Fluke
  • Product Code:NR-SP-Fluke-17B-MAX
  • Reward Points:112
  • Availability:In Stock
  • रo 13,331.64

  • Ex Tax:रo 11,298.00
  • Price in reward points:11298

Related Products

Fluke 101 Digital Multimeter

Fluke 101 Digital Multimeter

Designed for basic electrical tests, the Fluke 101 digital multimeter offers reliable measurements f..

रo 4,426.18 Ex Tax:रo 3,751.00

Fluke 106 Palm-sized Digital Multimeter

Fluke 106 Palm-sized Digital Multimeter

The Fluke 106 digital multimeter is made to fit the way you work! It is designed to fit in the palm ..

रo 5,900.00 Ex Tax:रo 5,000.00

Fluke 17B+ Digital Multimeter

Fluke 17B+ Digital Multimeter

Your job requires that you have a rugged, reliable and accurate digital multimeter. The Fluke 17B+ d..

रo 12,568.18 Ex Tax:रo 10,651.00

Tags: Fluke, Digital, Multimeter

The product is currently Out-of-Stock. Enter your email address below and we will notify you as soon as the product is available.

Name
Email
Phone
Comments